- PAPANIKOLI 1A – 1077 – NICOSIA – CYPRUS
- 0035722000125
- This email address is being protected from spambots. You need JavaScript enabled to view it.
THE UPS COMES WITH AN ADAPTER FROM EU SCHUKO TO UK SOCKET
High performance single-phase ON-LINE UPS with double conversion topology and Power Factor = 0.9. The Neoline Pro UPS provide excellent protection for critical loads and the elimination of all surges and disruptive noise. With zero transfer time, pure sine wave output and the ability to support different loads, it is the optimum solution for integrated home and IT equipment protection from costly interruptions. They also support Rack / Tower layout configuration.
Features:
• High frequency on-line double conversion technology
• DSP (Digital signal processors) control technology
• Output power factor 0.9
• Auto sensing frequency 50 / 60Hz frequency conversion
• Cold start
• Quick and stable charging, 90% capacity restored in 4 h (standard model UPS)
• Effective software and hardware protection
• Settable delayed start when power is restored
• Hot-swappable battery
• Advanced battery management (ABM)
• Multiple functions settable via LCD: output voltage, EOD, auto-start, bypass mode, ECO mode and frequency conversion mode
• Optional USB, RS485 card, AS400 dry contacts, SNMP card, SMS alarms, EPO function, MBS (External maintenance bypass switch)
Warranty (Repair - Replacement): | |
24 months | |
Capacity | 3 kVA / 2700 W |
INPUT | |
Rated voltage | 208 / 220 / 230 / 240 Vac |
Voltage range | 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 280 Vac (no derating); 280 ~ 300 Vac (derating 50%) |
Frequency | 40 ~ 70 Hz (auto-sensing) |
Power factor | ≥ 0.99 |
Bypass voltage range | - 25% ~ + 15% settable |
Total harmonic distortion | ≤ 6% |
OUTPUT | |
Voltage | 208 / 220 / 230 / 240 Vac (settable via LCD) |
Voltage regulation | ± 1% |
Frequency | 45 ~ 55 Hz or 55 ~ 65 Hz (synchronized range); 50 / 60 Hz ± 0.1 Hz (battery mode) |
Waveform | Sinusoidal |
Power factor | 0.9 |
Total harmonic distortion (THDv) | ≤ 2% (linear load), ≤ 5% (non-linear load) |
Crest factor | 3:1 |
Overload | 105% ~ 125% for 1 min, 125% ~ 150% for 30 s, > 150% for 300 ms |
BATTERIES | |
DC voltage | 72 V (S) |
Inbuilt battery | 6 × 9 Ah |
Charging current (max.) | 1 A |
Recharge time | Standard model: 90% capacity restored in 4 hours; Long time model: depend on the capacity of battery |
SYSTEM | |
Efficiency | ≥ 92% (Mains mode) ≥ 87% (Battery mode) ≥ 97% (ECO mode) |
Transfer time | Mains mode to battery mode: 0 ms Inverter mode to bypass mode: 4 ms (typical) |
Protections | Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection |
Communications | RS232 (standard), USB / RS485 / dry contacts / SNMP (optional) |
Display | LCD + LED |
Standards | EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 62040-1 |
OTHERS | |
Operating temperature | 0°C ~ 40°C |
Storage temperature | - 25 ~ 55°C (without batteries) |
Relative humidity | 0 ~ 95% (non-condensing) |
Altitude | ≤ 1000 m, derating 1% for each additional 100 m |
IP rating | IP 20 |
Noise level at 1m | ≤ 50 dB |
Dimensions (W × D × H) (mm) | 440 x 560 x 88 |
Packaged dimensions (W × D × H) (mm) | 545 x 690 x 201 |
Net weight (kg) | 26.8 |
Gross weight (kg) | 29.7 |